Inverter · Hybrid

SRNE HESP4880U200-H

SRNE HESP4880U200-H hybrid solar inverter.

Specifications

Max. Peak Power17,600W
Rated Frequency50/60Hz
Rated Output Power8800W
Load Motor Capacity5HP
Max. PV Input Power5500W/5500W
Battery Voltage Range40~60Vdc
Rated Battery Voltage48Vdc
Product family configurationUS | Split Phase | 2 MPPTs

How to read this record

  • Continuous output is what the inverter can hold for hours. Surge is a short overload for motor starts and is often double the continuous rating.
  • Battery voltage fixes the bank topology. A 48 V inverter needs a 48 V bank, and the charge current must be within the battery's limit.
  • Maximum PV voltage and the MPPT window are different limits. A string can be inside the MPPT window and still exceed the maximum PV voltage when cold.

Datasheet and manual

Check it fits your design

Specifications change with revisions and firmware. Confirm the exact model with the manufacturer, then check the battery voltage, charge current, MPPT window and communication protocol against the rest of the system.

More specifications

Record last updated 19 October 2026. Confirm the model revision with the manufacturer before ordering.

Back to the product spec database