Inverter · Hybrid
SRNE HESP48150UBH3
SRNE HESP48150UBH3 hybrid solar inverter.
Specifications
| Max. Peak Power | 30000W |
|---|---|
| Max. Output Power | 16500W |
| Rated Output Power | 15000W |
| Max. PV Input Power | 24000W |
| Rated Output Voltage | 230/400VAC three-Phase |
| Battery Voltage Range | 40V-60V |
| Max. PV Input Current | 26A+26A+26A |
| Product family configuration | US | Three Phase | 3 MPPTs |
How to read this record
- Continuous output is what the inverter can hold for hours. Surge is a short overload for motor starts and is often double the continuous rating.
- Battery voltage fixes the bank topology. A 48 V inverter needs a 48 V bank, and the charge current must be within the battery's limit.
- Maximum PV voltage and the MPPT window are different limits. A string can be inside the MPPT window and still exceed the maximum PV voltage when cold.
Datasheet and manual
Check it fits your design
Specifications change with revisions and firmware. Confirm the exact model with the manufacturer, then check the battery voltage, charge current, MPPT window and communication protocol against the rest of the system.