Inverter · Off-grid

SRNE ASP48120SH3

SRNE ASP48120SH3 off-grid solar inverter.

Specifications

Switch Time10ms(typical)
Rated Frequency50/60Hz
Max. Output Power24000VA
Rated Output Power12000W
Load Motor Capacity6HP
Rated Output Voltage230/400Vac
Phase Rated Output Power4000W
Product family configurationEU | Three Phase | 2MPPTs

How to read this record

  • Continuous output is what the inverter can hold for hours. Surge is a short overload for motor starts and is often double the continuous rating.
  • Battery voltage fixes the bank topology. A 48 V inverter needs a 48 V bank, and the charge current must be within the battery's limit.
  • Maximum PV voltage and the MPPT window are different limits. A string can be inside the MPPT window and still exceed the maximum PV voltage when cold.

Datasheet and manual

Check it fits your design

Specifications change with revisions and firmware. Confirm the exact model with the manufacturer, then check the battery voltage, charge current, MPPT window and communication protocol against the rest of the system.

More specifications

Record last updated 19 October 2026. Confirm the model revision with the manufacturer before ordering.

Back to the product spec database